Publication:
Safety, efficacy, and durability of stent-assisted coiling treatment of M2 (insular) segment MCA aneurysms

Placeholder

Departments

School / College / Institute

Organizational Unit
Organizational Unit
SCHOOL OF MEDICINE
Upper Org Unit

Program

KU Authors

Co-Authors

Berdikhojayev, M.
Cay, F.
Barburoğlu, M.
Nurzhan, S.
Sencer, S.
Arat, A.

Publication Date

Language

Embargo Status

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

Background and Purpose: Most distal MCA aneurysms are located within the insular segment, which lies between the limen insulae and circular sulcus. However, experience is limited in the microsurgical and endovascular management of insular segment MCA aneurysms. In this multicenter retrospective case series, we aimed to investigate the safety, efficacy, and durability of stent-assisted coiling for treatment of insular segment MCA aneurysms. MATERIALS and METHODS: A retrospective review was performed to identify patients with insular MCA aneurysms that were treated with stent-assisted coiling. The technical success of the procedures and the initial and follow-up clinical and angiographic outcomes were assessed. Periprocedural and delayed complications were reviewed. RESULTS: Twenty-seven aneurysms in 27 patients with a mean age of 53.3 (SD,11.3) years were included. The mean size of the aneurysms was 6.3 (SD 2.6) mm. Endovascular procedures were successfully performed in all patients. Immediate postprocedural angiography revealed complete aneurysm occlusions in 81.5%. Periprocedural complications developed in 7.4% without causing permanent morbidity. A delayed thromboembolic complication resulted in a minor permanent morbidity in 1 patient (3.7%). There was no mortality. The mean duration of angiographic follow-up was 19.5 (SD, 9.8) months. The last follow-up examinations showed complete occlusion in 92.6%. During the follow-up period, none of the treated aneurysms showed recanalization. CONCLUSIONS: The results of this study demonstrate that stent-assisted coiling with a low-profile self-expandable stent is a feasible and relatively safe technique for endovascular treatment of insular segment complex MCA aneurysms. Additionally, it provides an effective and durable treatment for insular MCA aneurysms.

Source

Publisher

Amer Soc Neuroradiology

Subject

Clinical Neurology, Neuroimaging, Radiology, Nuclear Medicine Medical Imaging

Citation

Has Part

Source

American Journal of Neuroradiology

Book Series Title

Edition

DOI

10.3174/ajnr.A7461

item.page.datauri

Link

Rights

Copyrights Note

Endorsement

Review

Supplemented By

Referenced By

0

Views

0

Downloads

View PlumX Details