Publication:
Synchronous PIV measurements of a self-powered blood turbine and pump couple for right ventricle support

dc.contributor.coauthorÇetinkaya, Emre
dc.contributor.departmentDepartment of Mechanical Engineering
dc.contributor.kuauthorUçak, Kağan
dc.contributor.kuauthorKarataş, Faruk
dc.contributor.kuauthorPekkan, Kerem
dc.contributor.otherDepartment of Mechanical Engineering
dc.contributor.schoolcollegeinstituteCollege of Engineering
dc.date.accessioned2024-12-29T09:39:46Z
dc.date.issued2024
dc.description.abstractA blood turbine-pump system (iATVA), resembling a turbocharger was proposed as a mechanical right-heart assist device without external drive power. In this study, the iATVA system is investigated with particular emphasis on the blood turbine flow dynamics. A time-resolved 2D particle image velocimetry (PIV) set-up equipped with a beam splitter and two high speed cameras, allowed simultaneous recordings from both the turbine and pump impellers at 7 different phased-locked instances. The iATVA prototype is 3D printed using an optically clear resin following our earlier PIV protocols. Results showed that magnetically coupled impellers operated synchronously. As the turbine flow rate increased from 1.6 to 2.4 LPM, the rotational speed and relative inlet flow angle increase from 630 to 900 rpm, and 38 to 55% respectively. At the trailing edges, backflow region spanned 3/5 of the total passage outlet flow, and an extra leakage flow was observed at the leading edge. For this early turbine design, approximately, 75% of the turbine blade passage was not contributing to the impulse operation mode. The maximum non-wall shear rate was ~ 2288 s−1 near to the inlet exit, which is significantly lower than the commercial blood pumps, encouraging further research and blood experiments of this novel concept. Experimental results will improve the hydrodynamic design of the turbine impeller and volute regions and will be useful in computational fluid dynamics validation studies of similar passive devices. © The Author(s) 2024.
dc.description.indexedbyWoS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue1
dc.description.openaccessGold Open Access
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuTÜBİTAK
dc.description.sponsorsFunding was provided by European Research Council (ERC) Proof of Concept BloodTurbine, and TUBITAK B\u0130DEB\u20142247A\u2014120C139.
dc.description.volume14
dc.identifier.doi10.1038/s41598-024-70243-7
dc.identifier.issn2045-2322
dc.identifier.quartileQ1
dc.identifier.scopus2-s2.0-85202611932
dc.identifier.urihttps://doi.org/10.1038/s41598-024-70243-7
dc.identifier.urihttps://hdl.handle.net/20.500.14288/23089
dc.identifier.wos1301037700031
dc.keywordsBlood pump
dc.keywordsBlood turbine
dc.keywordsIATVA
dc.keywordsPIV
dc.keywordsRight heart failure
dc.keywordsRight ventricular
dc.keywordsRVAD
dc.keywordsVAD
dc.keywordsVentricular assist device
dc.languageen
dc.publisherNature Research
dc.sourceScientific Reports
dc.subjectBlood pump
dc.subjectHemodynamic
dc.subjectComputational fluid dynamics
dc.titleSynchronous PIV measurements of a self-powered blood turbine and pump couple for right ventricle support
dc.typeJournal article
dspace.entity.typePublication
local.contributor.kuauthorUçak, Kağan
local.contributor.kuauthorKarataş, Faruk
local.contributor.kuauthorPekkan, Kerem
relation.isOrgUnitOfPublicationba2836f3-206d-4724-918c-f598f0086a36
relation.isOrgUnitOfPublication.latestForDiscoveryba2836f3-206d-4724-918c-f598f0086a36

Files