<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
Magnetically controllable and degradable milliscale swimmers as intraocular drug implants

Loading...
Thumbnail Image

Departments

School / College / Institute

Item type:Organizational Unit,
Item type:Organizational Unit,
Item type:Organizational Unit,

Program

Organization Authors

Co-Authors

Bozuyuk, Ugur

Yildiz, Eray

Wang, Fan

Han, Mertcan

Karacakol, Alp Can

Sheehan, Devin

Yu, Yan

Date

Language

Embargo Status

No

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

Intraocular drug implants are increasingly used for retinal treatments, such as age-related macular degeneration and diabetic macular edema, due to the rapidly aging global population. Although these therapies show promise in arresting disease progression and improving vision, intraocular implant-based therapies can cause unexpected complications that require further surgery due to implant dislocation or uncontrolled drug release. These frequent complications of intraocular drug implants can be overcome using magnetically controllable degradable milliscale swimmers (MDMS) with a double-helix body morphology. A biodegradable hydrogel, polyethylene glycol diacrylate, is employed as the primary 3D printing material of MDMS, and it is magnetized by decorating it with biocompatible polydopamine-encapsulated iron-platinum nanoparticles. MDMS have comparable dimensions to commercial intraocular implants that achieve translational motions in both aqueous and vitreous bodies. They can be imaged in real-time using optical coherence tomography, ultrasound, and photoacoustic imaging. Thanks to their biodegradable hydrogel-based structure, they can be loaded with anti-inflammatory drug molecules and release the medications without disrupting retinal epithelial viability and barrier function, and decrease proinflammatory cytokine release significantly. These magnetically controllable swimmers, which degrade in a couple of months, can be used for less invasive and more precise intraocular drug delivery compared to commercial intraocular drug implants.

Source

Publisher

Wiley

Citation

item.page.haspartof

Source

Advanced Science

item.page.ispartofseries

item.page.edition

DOI

10.1002/advs.202507569

item.page.datauri

item.page.link

Rights

CC BY (Attribution)

Copyrights Note

Creative Commons license

Except where otherwise noted, this item's license is described as CC BY (Attribution)

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

Google Scholar
Scholar'da Ara ↗
2
Görüntülenme
3
İndirme
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators