<link rel="stylesheet" href="styles.f3b1fba60ec7970c.css">

Publication:
Experimental evaluation of the developmental mechanism underlying fractures at the adjacent segment

Loading...
Thumbnail Image

Departments

Item type:Organizational Unit,

School / College / Institute

Item type:Organizational Unit,

Program

KU-Authors

Organization Authors

Co-Authors

Özkaya, Mustafa

Demir, Teyfik

Yaman, Mesut Emre

Özalp, Hakan

Dalbayrak, Sedat

Date

Language

Embargo Status

N/A

Journal Title

Journal ISSN

Volume Title

Alternative Title

Abstract

Background Compression fractures at adjacent mobile segments have been reported as adjacent segment disease under trauma in several studies. In this study, the occurrence of fractures at the adjacent segment was evaluated experimentally under trauma. Methods Static testing of different fixation systems was performed to show their biomechanical performances. The ovine vertebrae fixed with rigid, dynamic, and semirigid systems were used as test samples. The stiffness values of the systems were obtained by testing the vertebrectomy models under compression bending, lateral bending, and torsion tests. In addition, their effects on the adjacent segments were experimentally evaluated within a drop mechanism. A free-fall drop mechanism was designed and manufactured. Next, 3.5-kg, 5-kg, and 7-kg weights were released from 1 m above the test samples to generate compression fractures. The occurrence of compression fractures was observed with the use of radiograph of test samples, which were obtained before and after the drop test. Results Dynamic and semirigid systems have advantages compared with rigid systems as the result of their lower stiffness values. Radiographs showed that epiphysis fractures occurred at fixed and adjacent mobile segments, which were fixed with semirigid fixation. In addition, dynamic fixation well preserved the fixed and adjacent mobile segments under trauma. Conclusions The dynamic system with a polyetheretherketone rod can better preserve both adjacent and fixed segments. However, because of the cantilever beam effect, the semirigid system exhibits a great disadvantage.

Source

Publisher

Elsevier

Citation

item.page.haspartof

Source

World Neurosurgery

item.page.ispartofseries

item.page.edition

DOI

10.1016/j.wneu.2015.09.062

item.page.datauri

item.page.link

Rights

N/A

Copyrights Note

Rights and licensing

N/A

Endorsement

Review

Supplemented By

Referenced By

Related Patent

Related Goal

Google Scholar
Scholar'da Ara ↗
Altmetric
Dimensions
PlumX Metrikleri
BIP! Indicators