Publication:
The safety and accuracy of the fluoroscopic imaging during proximal femoral fixation: a computerized 3D reappraisal of the joint penetration risk

dc.contributor.departmentSchool of Medicine
dc.contributor.departmentMARC (Manufacturing and Automation Research Center)
dc.contributor.facultymemberYes
dc.contributor.kuauthorAslan, Lercan
dc.contributor.kuauthorDemirhan, Mehmet
dc.contributor.kuauthorLazoğlu, İsmail
dc.contributor.kuauthorSeyahi, Aksel
dc.contributor.kuauthorSubaşı, Ömer
dc.contributor.schoolcollegeinstituteSCHOOL OF MEDICINE
dc.contributor.schoolcollegeinstituteResearch Center
dc.date.accessioned2024-11-09T23:50:18Z
dc.date.issued2021
dc.description.abstractBackground: To assess the success of proximal cephalomedullary nailing operations for treating trochanteric fractures, surgeons utilize 2D fluoroscopy to observe the relative positions of the femoral head and the implant. One distance-based risk parameter, observed from the AP and Lateral projections, is the Tip-Surface Distance(TSD) that dictates how close to the outer cortex should the implant tip be residing to avoid post-surgical complications such as cut-out or joint penetration. In this study, the safety and the accuracy of the orthogonal fluoroscopic imaging were evaluated. Methods: A femoral head model was created and the risk zone was defined as a hemispherical shell of 5 mm thickness beneath the subchondral cortex, which should not be violated during screw insertion. The remaining hemisphere beneath the risk zone was designated as the safe zone. To assess the effect of head size, each simulation was conducted for 34, 47, and 60 mm diameter(Dfemur) femoral heads. The rate of safe zone violation was calculated for all possible screw endpoints with a TSD of at least 5 mm on fluoroscopic orthogonal views (TSDAP and TSDLat). Results: The minimum risk of joint penetration was achieved when the TSDAP/TSDLat ratio was 1. For Dfemur of 34 mm there was a risk of 91.7% of the safe zone violation when each TSDAP and TSDLat were 5 mm and 0% for 9 mm. For Dfemur of 47 mm, the risk was 92.2% for 5 mm and 0% for 11 mm. For Dfemur of 60 mm, the risk was 92.3% for 5 mm and 0% for 13 mm. Safety maps were constructed for all possible TSD combinations for 34, 47, and 60 mm femoral heads. Conclusions: Depending solely on the orthogonal fluoroscopic images is not a safe and accurate technique for assessing joint penetration risk during proximal femoral fixation due to the spherical geometry of the femoral head. The screw tip can lie completely outside of the femoral head even when it appears inside, in both orthogonal fluoroscopic views. Evidently, when using TSD, more stringent distance limits should be chosen, contrary to the recommended 5 mm limit. Our safety maps for TSD combinations may be used to check the security of the implantation.
dc.description.fulltextNo
dc.description.harvestedfromManual
dc.description.indexedbyWOS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.openaccessNO
dc.description.peerreviewstatusN/A
dc.description.publisherscopeInternational
dc.description.readpublishN/A
dc.description.sponsoredbyTubitakEuN/A
dc.description.studentonlypublicationNo
dc.description.studentpublicationNo
dc.description.versionN/A
dc.identifier.WoSQuartileQ2
dc.identifier.doi10.1016/j.injury.2020.11.064
dc.identifier.eissn1879-0267
dc.identifier.embargoN/A
dc.identifier.endpage1455
dc.identifier.issn0020-1383
dc.identifier.issue6
dc.identifier.pubmed33257021
dc.identifier.scopus2-s2.0-85096848257
dc.identifier.startpage1450
dc.identifier.urihttps://doi.org/10.1016/j.injury.2020.11.064
dc.identifier.urihttps://hdl.handle.net/20.500.14288/14522
dc.identifier.volume52
dc.identifier.wos000655253400034
dc.keywordsProximal nailing
dc.keywordsTrochanteric fracture
dc.keywordsTip-Surface Distance
dc.keywordsFluoroscopy
dc.keywordsTip-apex distance
dc.keywordsInternal-fixation
dc.keywordsIntertrochanteric fractures
dc.keywordsFailure
dc.language.isoeng
dc.publisherElsevier Sci Ltd
dc.relation.affiliationKoç University
dc.relation.collectionKoç University Institutional Repository
dc.relation.ispartofInjury-International Journal of The Care of The Injured
dc.relation.openaccessN/A
dc.rightsN/A
dc.subjectCritical care medicine
dc.subjectEmergency medicine
dc.subjectOrthopedics
dc.subjectSurgery
dc.titleThe safety and accuracy of the fluoroscopic imaging during proximal femoral fixation: a computerized 3D reappraisal of the joint penetration risk
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.kuauthorAslan, Lercan
local.contributor.kuauthorSubaşı, Ömer
local.contributor.kuauthorDemirhan, Mehmet
local.contributor.kuauthorSeyahi, Aksel
local.contributor.kuauthorLazoğlu, İsmail
relation.isOrgUnitOfPublicationd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isOrgUnitOfPublication52df3968-be7f-4c06-92e5-3b48e79ba93a
relation.isOrgUnitOfPublication.latestForDiscoveryd02929e1-2a70-44f0-ae17-7819f587bedd
relation.isParentOrgUnitOfPublication17f2dc8e-6e54-4fa8-b5e0-d6415123a93e
relation.isParentOrgUnitOfPublicationd437580f-9309-4ecb-864a-4af58309d287
relation.isParentOrgUnitOfPublication.latestForDiscovery17f2dc8e-6e54-4fa8-b5e0-d6415123a93e

Files