Publication:
The safety and accuracy of the fluoroscopic imaging during proximal femoral fixation: a computerized 3D reappraisal of the joint penetration risk

dc.contributor.departmentN/A
dc.contributor.departmentN/A
dc.contributor.departmentN/A
dc.contributor.departmentN/A
dc.contributor.departmentDepartment of Mechanical Engineering
dc.contributor.kuauthorAslan, Lercan
dc.contributor.kuauthorSubaşı, Ömer
dc.contributor.kuauthorDemirhan, Mehmet
dc.contributor.kuauthorSeyahi, Aksel
dc.contributor.kuauthorLazoğlu, İsmail
dc.contributor.kuprofileFaculty Member
dc.contributor.kuprofilePhD Student
dc.contributor.kuprofileFaculty Member
dc.contributor.kuprofileFaculty Member
dc.contributor.kuprofileFaculty Member
dc.contributor.otherDepartment of Mechanical Engineering
dc.contributor.schoolcollegeinstituteSchool of Medicine
dc.contributor.schoolcollegeinstituteGraduate School of Sciences and Engineering
dc.contributor.schoolcollegeinstituteSchool of Medicine
dc.contributor.schoolcollegeinstituteSchool of Medicine
dc.contributor.schoolcollegeinstituteCollege of Engineering
dc.contributor.yokid145301
dc.contributor.yokidN/A
dc.contributor.yokid9882
dc.contributor.yokid52082
dc.contributor.yokid179391
dc.date.accessioned2024-11-09T23:50:18Z
dc.date.issued2021
dc.description.abstractBackground: To assess the success of proximal cephalomedullary nailing operations for treating trochanteric fractures, surgeons utilize 2D fluoroscopy to observe the relative positions of the femoral head and the implant. One distance-based risk parameter, observed from the AP and Lateral projections, is the Tip-Surface Distance(TSD) that dictates how close to the outer cortex should the implant tip be residing to avoid post-surgical complications such as cut-out or joint penetration. In this study, the safety and the accuracy of the orthogonal fluoroscopic imaging were evaluated. Methods: A femoral head model was created and the risk zone was defined as a hemispherical shell of 5 mm thickness beneath the subchondral cortex, which should not be violated during screw insertion. The remaining hemisphere beneath the risk zone was designated as the safe zone. To assess the effect of head size, each simulation was conducted for 34, 47, and 60 mm diameter(Dfemur) femoral heads. The rate of safe zone violation was calculated for all possible screw endpoints with a TSD of at least 5 mm on fluoroscopic orthogonal views (TSDAP and TSDLat). Results: The minimum risk of joint penetration was achieved when the TSDAP/TSDLat ratio was 1. For Dfemur of 34 mm there was a risk of 91.7% of the safe zone violation when each TSDAP and TSDLat were 5 mm and 0% for 9 mm. For Dfemur of 47 mm, the risk was 92.2% for 5 mm and 0% for 11 mm. For Dfemur of 60 mm, the risk was 92.3% for 5 mm and 0% for 13 mm. Safety maps were constructed for all possible TSD combinations for 34, 47, and 60 mm femoral heads. Conclusions: Depending solely on the orthogonal fluoroscopic images is not a safe and accurate technique for assessing joint penetration risk during proximal femoral fixation due to the spherical geometry of the femoral head. The screw tip can lie completely outside of the femoral head even when it appears inside, in both orthogonal fluoroscopic views. Evidently, when using TSD, more stringent distance limits should be chosen, contrary to the recommended 5 mm limit. Our safety maps for TSD combinations may be used to check the security of the implantation. (C) 2020 Elsevier Ltd. All rights reserved.
dc.description.indexedbyWoS
dc.description.indexedbyScopus
dc.description.indexedbyPubMed
dc.description.issue6
dc.description.openaccessNO
dc.description.publisherscopeInternational
dc.description.sponsoredbyTubitakEuN/A
dc.description.volume52
dc.identifier.doi10.1016/j.injury.2020.11.064
dc.identifier.eissn1879-0267
dc.identifier.issn0020-1383
dc.identifier.quartileQ2
dc.identifier.scopus2-s2.0-85096848257
dc.identifier.urihttp://dx.doi.org/10.1016/j.injury.2020.11.064
dc.identifier.urihttps://hdl.handle.net/20.500.14288/14522
dc.identifier.wos655253400034
dc.keywordsProximal nailing
dc.keywordsTrochanteric fracture
dc.keywordsTip-Surface Distance
dc.keywordsFluoroscopy
dc.keywordsTip-apex distance
dc.keywordsInternal-fixation
dc.keywordsIntertrochanteric fractures
dc.keywordsFailure
dc.languageEnglish
dc.publisherElsevier Sci Ltd
dc.sourceInjury-International Journal of The Care of The Injured
dc.subjectCritical care medicine
dc.subjectEmergency medicine
dc.subjectOrthopedics
dc.subjectSurgery
dc.titleThe safety and accuracy of the fluoroscopic imaging during proximal femoral fixation: a computerized 3D reappraisal of the joint penetration risk
dc.typeJournal Article
dspace.entity.typePublication
local.contributor.authorid0000-0003-1358-3236
local.contributor.authorid000-0002-8383-6000
local.contributor.authorid0000-0001-8411-7596
local.contributor.authorid0000-0002-1968-7127
local.contributor.authorid0000-0002-8316-9623
local.contributor.kuauthorAslan, Lercan
local.contributor.kuauthorSubaşı, Ömer
local.contributor.kuauthorDemirhan, Mehmet
local.contributor.kuauthorSeyahi, Aksel
local.contributor.kuauthorLazoğlu, İsmail
relation.isOrgUnitOfPublicationba2836f3-206d-4724-918c-f598f0086a36
relation.isOrgUnitOfPublication.latestForDiscoveryba2836f3-206d-4724-918c-f598f0086a36

Files